Labs abd Equipment




The HI-98194 measures 12 different water quality parameters and comes with a 4 metre cable.

  •  ORP
  •  Resistivity
  •  Temperature
  •  Dissolved Oxygen
  •  pH
  •  Salinity
  •  Conductivity & TDS

Specification

pH/mV Range   0.00 to 14.00 pH/± 600.0 mV
Resolution   0.01 pH/ 0.1 mV
Accuracy   ±0.02 pH/ ±0.5 mV
Calibration   automatic one, two or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
ORP Range   ±2000.0 mV
ORP Resolution   0.1 mV
ORP Accuracy   ±1.0 mV
ORP Calibration   automatic at one custom point (relative mV)
EC Range   0 to 200 mS/cm (absolute EC up to 400 mS/cm)
EC Resolution   Manual: 1?S/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; automatic: 1?S/cm from 0 to 9999 ?S/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
EC Accuracy   ±1% of reading or ± 1?S/cm whichever is greater
EC Calibration   automatic single point, with six standard solutions (84?S/cm, 1413?S/cm, 5.00mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range   0 to 400.0 ppt (g/L) (the maximum value depends on the TDS factor)
TDS Resolution   manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); automatic: 1ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 PPT(g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 pp (g/L)
TDS Accuracy   ±1% of reading or ±1 ppm (mg/L) whichever is greater
TDS Calibration   based on conductivity or salinity calibration
Resistivity Range   0 to 999999 ?.cm; 0 to 1000.0 k?.cm; 0 to 1.0000 M?.cm
Resistivity Resolution   dependent on resistivity reading
Resistivity Calibration   based on conductivity or salinity calibration
Salinity Range   0.00 to 70.00 PSU
Salinity Resolution   0.01 PSU
Salinity Accuracy   ±2% of reading or ±0.01 PSU whichever is greater
Salinity Calibration   based on conductivity calibration
Seawater  Range   0.0 to 50.0 ?t, ?0, ?15
Seawater  Resolution   0.1 ? t, ?0, ? 15
Seawater  Accuracy   ±1 ? t, ?0, ? 15
Seawater  Calibration   based on conductivity or salinity calibration
Dissolved Oxygen Range   0.0 to 500.0%, 0.00 to 50.00 ppm
DO Resolution   0.%; 0.01 ppm (mg/L)
DO Accuracy   0.0 to 300.0%; ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%; ±3% of reading; 0.00 to 30.00 ppm (mg/L); ±1.5% of reading or ±0.10 ppm (mg/L). whichever is greater; 30.00 ppm (mg/L) to 50.00 ppm (mg/L); ±3% of reading
DO Calibration   automatic one or two points at 0.100% or one custom point
Atmospheric Pressure Range   450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Atmospheric Pressure Resolution   0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Atmospheric Pressure Accuracy   ±3mm Hg within ±15°C from the temperature during calibration
Atmospheric Pressure Calibration   automatic at one custom point
Temperature Range   -5.00 to 55.00°C
Temperature Resolution   0.01°C
Temperature Accuracy   ±0.15°C
Temperature Calibration   Automatic at one custom point
Additional Specifications    
Maximum probe immersion   Depth - 20 metres
Temperature compensation   automatic from -5 to 55°C
 Logging Memory   45,000 records (continuous logging or log-on demand of all parameters
Logging Interval   one second to three hours
PC Connectivity   via USB (with Hanna PC software)
 Environment   0 to 50°C; RH 100% IP67
Battery Type/Life   1.5V AA batteries (4)/approximately 360 hours of continuous use without backlight (50 hours with backlight)